background image

7-26

Interface

CNC

(Customer Supplied)

HPR PAC

Dry Cutting System

4

3

2

1

1

A

4

3

2

A

B

C

D

B

C

D

141030

CONTROL BOARD

S301

1

2

J300

3

4

3 2 1

4

J303A

J303B

Serial ID

Dipswitch

Jumper Block

Machine Motion

CNC Interface Cable

Notes:

1) For single system installation set Serial ID (S301), Machine

Motion (J300), J104 & J105 as shown.

Relocate the white wire on TB2 from position #3 to position

#2. Connect customer supplied Remote On/Off cable in series

with the power supply and the gas console power switch.

Connect one terminal of the Remote On/Off cable to position

#2 on TB2 and the other terminal to position #3.

Refer to page 3 of the wiring diagram

Depress the Gas Console Power switch to the closed position (on position).

2) For a multi-system installation set up as described above, set jumpers as shown on the

multi-system interface page

3) The CNC will need a dedicated I/O for each system using the Remote On/Off feature

(contact should be rated for min. 24Vac, 0.5 Amp)

1

2

4
3

5

7
6

5

1

3
2

4

7
6

7

RED/BLK
RED

WHT

RED

Gas Console

078170

Gas Power Cable

Customer Supplied

Remote On/Off

J104

2

1

2

1

J105

Optional Remote On/Off

TB2

WHT

RED

RED/BLK
RED

6

2

1

1X1

* If a Hypertherm Automation controller is being used, and there are intermittent communication

failures (PS Link Failure), try removing the jumnpers on J104 and J105 on the control board, and the

termination jumper (J6 or J8) on the serial isolation board in the controler. Only remove

the termination jumper on the serial isolation board that is connected to the HPR

power supply. See figure below for details.

BMD

J2

BTR

J7

RS-232

J9

RS-422

BHST

AHST

J3

AMD

J5

J6

RS-422

J10

RS-232

ATR

J8

J1

SV

RIBBO

N

C

A

BL

E

Serial isolation board in a Hypertherm Automation controller

1 2 3 4 5 6 7 8

ON

ELEC SCH:HPR400XD PWR SPLY W/AUTO

E

013374

SHEET 22 OF 24

S301

1 2 3 4 5 6 7 8

All switches are in the OFF position

Dipswitch setting example: As shipped

2

1

3 4

5 6

7 8

ON

ON