Optional multi-system interface – Hypertherm HPR260 Auto Gas Instrukcja Obsługi

Strona 226

Advertising
background image

7-24

120

RX

Termination

Termination

120

TX

4

3

2

1

1

A

4

3

2

A

B

C

D

B

C

D

Unit 1

Interface

CNC

(Customer Supplied)

041909

CONTROL BOARD

1 2 3 4

S100

1 2

J303

3 4

3

2

1

4

J300A

J300B

CNC Interface Cable

J300A

S100

J300B

J303

3

2

1

4 1

CONTROL BOARD

041909

2 3 4

Unit 2

J300A

S100

J300B

J303

3

2

1

4 1

CONTROL BOARD

041909

2 3 4

Unit 3

J300A

J300B

S100

J303

1 2 3 4 1

041909

CONTROL BOARD

4

3

2

Unit 4

CNC Interface Cable

CNC Interface Cable

CNC Interface Cable

Serial ID

Dipswitch

Machine Motion

Jumper Block

Jumper Block

Machine Motion

Dipswitch

Serial ID

Jumper Block

Machine Motion

Dipswitch

Serial ID

Jumper Block

Machine Motion

Dipswitch

Serial ID

J106

2

1

J107

1 2

J106

1 2

1 2

J107

J106

1 2

1 2

J107

J106

1 2

1 2

J107

Optional Multi-System Interface

1

3

2

4

3

1 2

4

1 2 3 4

5 6 7 8

1

3

2

4

7

5 6

8

6

5

7 8

HPR PAC

Dry Cutting System

HPR PAC

Dry Cutting System

HPR PAC

Dry Cutting System

HPR PAC

Dry Cutting System

D

18

Notes:

1) For single system installations set Serial ID (S100), and Machine Motion (J303) as shown in Unit 1,
jumpers J106 and J107 must be closed

2) On multi-system installations refer to the illustration.
Jumpers J106 and J107 are left open on all systems except for the very last system where
they are in the closed position
Termination resistors (120-ohm) or termination jumpers must be installed/set at the CNC for
each of the RS-422 RX and TX signal pairs.

3) Use only the first four dipswitch settings, they are the same as on the 041808 control
board

5

Dipswitch setting example:

Switch 1 is in the ON position.
Switches 2-8 are in the OFF position.

*

*

* If a Hypertherm Automation controler is being used, and there are intermittent communication

failures (PS Link Failure), try removing the jumpers on J106 and J107 on the control board, and the
termination jumper (J6 or J8) on the serial isolation board in the controler. Only remove the
termination jumper on the serial isolation board that is connected to the HPR power supply. See
sheet 19 of 20 for more details.

Advertising