Set the value by pressing SEL and confirm your setting by pressing 
SET. Set the upper limit in the same way. 
Exit setting mode by pressing MODE. Press and hold SEL to activate 
the heart rate alarm. When the heart rate alarm is activated, the alarm 
symbol
will appear on and an alarm will sound when the measured
heart rate is not within the set zone "BEEP-BEEP...BEEP-
BEEP...BEEP-BEEP". 
If the measured heart rate is at or above 99% of the maximum heart 
rate the max. heart rate alarm will sound. "BEEP-BEEP-BEEP-BEEP-
BEEP-BEEP". The max. heart alarm is independant of the training zone 
and the heart rate alarm of the training zone. 
 
Calories, fat burn and BMI
CALORIE
KALORIEN
CALORIES
CALORIAS
 
The lower row will show the burned calories 
CALORIE
KALORIEN
CALORIES
CALORIAS
Press SET to switch to the display of fat burn in gram
FAT BURN
FETT
CONSGRAISSES
GRASA
or to the display of your BMI
BMI
BMI
IMC
IMC
 
In the display for calorie burn or fat burn the values can be reset by 
pressing and holding SET. 
 
Note: To increase the accuracy of the calorie and fat burn displays your 
age and weight must be set correctly. 
 
Note: The counter for fat burn is only activated while your heart rate is 
above 120 beats per minute. 
 
- 16 -
Notes on the BMI 
The BMI is a statistical measurement that can be used to judge a 
persons weight. For adults, a value between 18.5 and 25 is considered 
normal. Values below 18.5 are considered "underweight". Values above 
25 are considered "overweight". Values above 30 are considered 
"Obese". 
The BMI is only a coarse guideline because it does not take a persons 
body type and body composition into consideration. 
Fitness
FITNESS
LEVEL
FITNESS
LEVEL
NIV FORM
PHYSIQ
NIVEL
FIT
After your training, immediately press SET. A 5 minute countdown will 
start (cool down phase). 
The bar will show the remaining time. On the left side of the display the 
heart rate at the beginning of cool down is shown. On the right side of 
the display the current heart rate is shown. The countdown time is 
shown on the bottom row of the display. 
After 5 minutes your fitness level will appear. 
 
Fitness level 
Heart rate
6
>130
5
130-120
4
120-110
3
110-105
2
105-100
1
<100
- 17 -
Coded transmission
The chest belt's transmissions are digitally coded to prevent 
interference if you are training with a training partner who is using an 
identical watch and chest belt. 
When using the chest belt for the first time, a random channel is 
selected automatically. The channel is briefly displayed at the top of the 
display upon entering the heart rate display mode. The available 
channels are CH10, CH11, CH12, CH13 and CH14. 
The channel can be changed by briefly removing the battery from the 
chest best and reinserting it. The chest belt will randomly select a 
channel and after approx. 1 minute the heart rate and the new channel 
will appear on the display of the watch. 
Troubleshooting
The heart rate is not shown or is shown incorrectly 
Make sure the chest belt is positioned correctly and fits well. 
Your skin should not be too dry or too cold. 
The contact areas can be slightly moistened to improve function. 
Electromagnetic interference may have an adverse effect on reception. 
The distance between watch and chest belt must be under 70cm. 
Other heart rate measuring devices within a 2m range may also cause 
interference. 
Wireless bicycle computers may cause interference. 
The batteries may be low and require replacing. 
 
The display is unreadable / the light does not work 
Replace the batteries. 
- 18 -
Disposal
Disposal of the electronic appliance 
This electronic appliance may not be disposed of with normal 
household waste. Dispose of the unit at an approved disposal 
facility or at your local recycling centre. Please observe the 
current rules and regulations when disposing of the appliance. 
Contact the disposal system if in doubt. 
 
Disposal of the batteries 
Please dispose of your batteries properly in containers especially 
set up at retailers. Batteries do not belong in household waste. 
Dispose of the batteries at an approved disposal facility or at your 
local recycling centre. Contact the disposal system if in doubt. 
Replacement of battery
Battery replacements should be performed by an expert to avoid 
damaging the case or gaskets. 
 
Battery low indicator
If the battery voltage on the chest belt battery drops below the voltage 
required for normal operation, 
TXBELT
LO BAT
TXGURT
BATT
SNGLTX
PILE
TXBCIN
BAT BA
will appear on the display. Replace the battery of the chest belt as 
described in the chapter "Chest belt".
- 19 -
Warranty
We provide a 3-year warranty for this item. The warranty period starts 
from the date of sale (receipt, proof of purchase). Within this period we 
rectify all faults which are attributable to material and manufacturing 
defects at no cost. For damage which is caused by improper treatment, 
e.g. dropping, knocking, or water damage, there is no warranty claim. 
Declaration of conformity
If used as intended this product conforms to the basic standards of § 3 
and the other relevant provisions of the FTEG (Section 3 of the R&TTE 
directive). 
You can request the declaration of conformity here: 
[email protected] 
Water resistance
Water resistant up to 3 bar. The bar value specifies the atmospheric 
overpressure which is applied during testing (DIN 8310). 
 
- 20 -
Water resistance of the chest belt
Water resistance according to IEC 60529 IPx7: 30m 
 
Technical specifications
 
Wrist watch 
Operating temperature
0-50°C
Dimensions
4,4 x 5,0 cm
Display
2,4 x 1,8 cm
Weight
51 g
 
Chest belt 
Operating temperature
0-50°C
Dimensions
7 x 3,3 x 1,2 cm
Frequency
110 kHz
Weight
51 g