Maintenance and cleaning

c

Danger: make sure that the gas alarm is
not live when maintaining or cleaning the
device.

o Clean the casing of the gas alarm with a

dust cloth or a damp cloth. Use a mild
detergent (no solvents) to clean the plastic
surface.

o Remove all deposits of dust from the sensor

openings regularly with a brush.

o Check regularly that the device is working

properly (see section „Function test“).

o Replace the gas alarm after it has been in

use for approximately 5 years.

Disposal

Please take all packaging materials to a dis-
posal facility in your city or district.
In accordance with European Directive
2002 / 96 / EC on used electrical and electronic
appliances and its implementation in national
law, used electrical appliances must be collected
separately and recycled in an ecologically
compatible manner.
Please dispose of the alarm at the end of its
useful life at a disposal facility in your city or
district.

Warranty

This device has a warranty of 3 years from the
date of purchase. The device was manufac-
tured with care and inspected thoroughly
before delivery. Please keep your receipt as
proof of purchase. If you have a claim under
the warranty, please contact the service office
for your country. This is the only way to ensure
that your device can be sent in free of charge.
This warranty is only valid for the first pur-
chaser and is not transferable.
The warranty furthermore covers material or
manufacturing defects only. It does not apply
to wear parts or damage to fragile parts. The
product is solely intended for private use and
not for commercial use. No claim for damages
may be brought in the event of fire or explo-
sion. An alarm is no substitute for insurance
cover and does not replace your duty of care.
In the event of incorrect and / or improper han-
dling, the use of force or any work on the
device that is not performed by the service
office, the warranty shall expire. This warranty
does not restrict your statutory rights.

Troubleshooting

Fault

Cause

Remedy

The gas alarm responds

when there is no actual

gas leak.

The gas alarm will respond to
fumes from cleaning agents,
paint, lacquers, sprays, cooking
fumes, tobacco smoke and
smoke from candles.

Remove the source of the
fumes.

The gas alarm fails the

function test.

The service life of the gas
alarm expires after approx.
5 years of operation.

Replace the gas alarm.

The gas alarm does not

work.

The power supply is faulty.

Make sure that the power
supply is free of faults.

FAULT-LED flashes

See section on
“Fault display”

See section on
“Fault display”