Dexaplan GA 617 Instrukcja Obsługi

Strona 3

Advertising
background image

On the rear of the casing (see Fig. B):

g

Rear of casing

h

Mounting fixture

i

12 V DC terminal screws

j

Cable guide

k

Side and lower sensor openings

Technical data

Gas alarm:
Power supply:

12 Volt DC (±10%)
mains adapter (deliv-
ered with the gas
alarm) or on-board
power supply system

Current consumption: max. 150 mA
Gas sensor:

hot-wire method

Sensitivity/alarm
threshold:

corresponds to a con-
centration of approx.
12 % of the relevant
lower explosive limit

Propane:

0.2 %

Butane:

0.17 %

Methane
(town gas/natural gas): 0.53 %
Alarm signal:

loud high-frequency
tone

Volume:

85 dB(A) 3m

Operating temperature: -10 °C to +40 °C
Relative air humidity: max. 95 %
Material:

ABS plastic

Dimensions:

35 x 85 x 85 m (h x w x l)

Weight:

approx. 100 g

Protection class:

III

Mains adapter (delivered with the gas

alarm):
Power supply:

230 V ~ 50 Hz

Current consumption:

60 mA

Current output:

12 Volt DC 300 mA

Connecting cable length: approx. 2 m

Safety instructions

The following instructions are for your own
safety and satisfaction when operating the GA
617 gas alarm. Please note that non-compli-
ance with these safety instructions can lead to
a serious risk of accident.

Explanation of the symbols and terms used:

c

Danger! Failure to observe this instruc-
tion endangers life and health.

m

Caution! Failure to observe this instruc-
tion poses a risk to property.

c

Danger!

• Do not leave small children unsupervised

5

GB

KOE217_GA617_Content_LB4A.indd 5

20.11.2007 16:01:58 Uhr

Advertising