Trouble shooting, Installation accessories – MPM 12-KPO-04 Instrukcja Obsługi

Strona 27

Advertising
background image

TROUBLE SHOOTING

Before contacting professional service, please firstly check it yourself referring to

the followings.

Trouble

Check

Solution

The unit doesn’t

operate at all.

Is power fail?

Is plug out?

Is power fuse or switch off?

Is the set time suitable?

Is water full alarm on?

It is normal.

Insert the plug into the socket

steadily.

Change the fuse or switch on.

Change the set time.

Pour the water.

Cooling/Hating

efficiency is not

good

Is air inlet or outlet blocked?

Is there any other heat source in

room?

Are air filters very dirty?

Is the set temperature suitable?

Is fan speed set at low?

Clear off the blocks.

Move the heat source.

Clean the air filter.

Change temperature.

Select suitable fan speed.

Too

noisy

and

vibration

It is the inner liquid (refrigerant)

flowing inside.

Is it inclined?

It is normal.

Place it in a flat place.

The unit starts and

stops frequently

Is the voltage normal?

Is the exhaust tube fixed rightly

or is it bended?

Have you added extra exhaust

tube

Turn off the unit if the voltage is

abnormal.

Set the exhaust tube correctly.

Remove the extra tube.

Stop running and pull the plug out in case something enumerated below

happens. Then contact the professional service for help.

·

The fuse and switch often break.

·

The power cord superheat or sleeve of the cord is broken.

·

There is abnormal odor or smoke comes out of the unit.

Self-diagnosis function

Check code

Diagnosis of malfunction

E2

Room temperature faults

E3

Faulty coil temperature

E5

Unit faults (Restart the unit)

Note: When display E4, it means that the coil is defrosted. That is the normal status.

INSTALLATION ACCESSORIES

Description:
Flexible exhaust hose with adapters

……2/set

Stretch from

YPC1-07/08/09:14” (36cm) up to 59” (150cm)

YPC1-12/14/15:15” (38cm) up to 59” (150cm)
Window exhaust adapter (flat mouth)

……1pc

Adjustable window slider kit

…………………2/set

From 35 3/8” (90cm) up to 51 1/8” (130cm)
Screw (the length is 3/8”)

……………………1pc

Water cup ………………………………………1pc

INSTR.indd...27

2011-01-10...11:11:20

Advertising