Remote control, Operation methods – MPM 12-KPO-04 Instrukcja Obsługi
Strona 20
20
SVK
REMOTE CONTROL
Power Press this button to turn/off the unit.
Timer Press this button to set the timer.
Swing Press this button to make the vertical
louver swing automatically
Vary from Celsius degree to Fahrenheit
degree.
Cool Press this button to choose Cool mode.
Heat Press this button to choose Heat mode.
Dry Press this button to choose Dry mode.
Fan Press this button to choose Fan mode.
Up
Press Up or Down button to set temperature
Down or adjust the time in Timer mode.
High Press this button to select high fan speed.
Med Press this button to select middle fan speed.
Low Press this button to select low fan speed.
Econ Press this button to a set energy saving mode only in Cool and Heat
mode. The set temperature is 27℃ in cool mode and 23℃ heat mode The
fan speed is low. These data can’t be changed.
NOTE: To vary from Celsius to Fahrenheit by control panel, press both Up and Down button
at least 2 seconds.
OPERATION METHODS
Timer set
1.Set timer-off
Press the Timer button when the unit is on. The LED will flash five
Times. During this period press Up or Down button to adjust set time from 0.5h to 24h. It
will vary 0.5h each time in 3h and 1h each time hereafter. The set time will flash 5 times
after adjusting. When it will display temperature again. Once the set time end, the unit will
turn off automatically.
2. Change the set time
When Timer is on, you can check remnant time by pressing Timer button. It will flash 5
times. Press Up or Down button to adjust set time. The set time can also be cancelled if
you press the Timer button once again during the flashing time.
3.Set timer-on
Press the Timer button when the unit is off. Same as timer-off set. Once the set time end,
the unit will turn on automatically.
Cooling/Heating and Dehumidifying operation
1.Cooling/Heating operation
Press Mode button or
/
to choose Cool/heat mode.
Press Up or Down button or
to set a proper room temperature.
The range is 18~30℃(64-84°F). The temperature will increase or decrease 1℃ or 1°F
each time.
Press Speed button or
to choose a proper fan speed.
Press Swing button or
to adjust the direction of vertical louver.
Adjust horizontal louver by hand.
2.Dehumidifying operation
Press Mode button or
to choose Dry mode. The fan speed is Low,
LED displays room temperature. These cannot be adjusted.
NOTE:
1. In cool mode, when the water Injection indicates lights, you can inject some water
through the injection port before cooling operation (no longer than High level).
2. You should drain water with the drainpipe in heat and dehumidifying mode. The
unit will stop work when water level exceeds the high level.
3. Do not use air exhaust duct when in Dry or Fan modes
4. If your room is directly exposed to the sun, draw the curtains please.