Cleaning and maintenance, Technical specifications – Velleman VDP100BM Instrukcja Obsługi
Strona 5
VDP100BM
V. 03 – 06/06/2013
5
©Velleman nv
DMX512 Chain with Termination
A DMX terminator is recommended for installations where the DMX cable has to run a long
distance or is in an electrically noisy environment (e.g. discos). The terminator prevents
corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR
plug with a 120 Ω resistor between pins 2 and 3, which is then plugged into the XLR output
socket of the last device in the chain.
DMX Start Address Selection
All DMX-controlled devices need a digital start address so that the correct device responds to
the signals. This digital start address is the channel number from which the device starts to
“listen” to the DMX controller. The same starting address can be used for a whole group of
devices or an individual address can be set for every device.
When all devices have the same address, all the units will “listen” to the control signal on one
particular channel. In other words: changing the settings of one channel will affect all devices
simultaneously. If you set individual addresses, each device will “listen” to a separate channel
number. Changing the settings of one channel will only affect the device in question.
In case of the 1-channel mode, you will have to set the start address of the first unit to 1
(CH1), the second to 2 (CH2), the third to 3 (CH3), and so on. The highest start address
is 512.
Enter the correct number through the DIP-switches located on the backside of the device.
6.
Cleaning and Maintenance
•
All screws should be tightened and free of corrosion.
•
The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension,
trussing) should not be deformed, modified or tampered with; e.g. do not drill extra holes in mounting
supports, do not change the location of the connections…
•
Mechanically moving parts must not show any signs of wear and tear.
•
The electric power supply cables must not show any damage. Have a qualified technician maintain the
device.
•
Disconnect the device from the mains prior to maintenance activities. Let the device cool down.
•
Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
•
Wipe the device regularly with a dry, lint-free cloth. Do not use alcohol or solvents.
•
Do not immerse the device in any liquid.
•
There are no user-serviceable parts, apart from the fuse.
•
Contact your dealer for spare parts if necessary.
7.
Technical Specifications
power supply
max. 230 VAC / 50 Hz
power consumption
max. 300 W
fuse
10 A, 250 VAC (5 x 20 mm) (order code FF10N)
dimensions
490 x 380 x 440 mm
total weight
11.5 kg
max. ambient temperature
45 °C
max. housing temperature
130 °C
optional bubble liquid
VDLBL5 (5 L)
Use this device with original accessories only. Velleman nv cannot be held responsible in the event
of damage or injury resulting from (incorrect) use of this device.
For more info concerning this product and the latest version of this manual, please visit our website
www.hqpower.eu.
The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this
manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the
prior written consent of the copyright holder.