4.
Installation
Bubble Liquid
1.
Put the liquid into the basin in the front. Do not overfill and respect the markings.
2.
If the machine is not used for a long time, please let the liquid out through the pump
(see picture) on the backside of the machine.
Fuse
Only fit or replace a fuse when the device is unplugged from the mains.
Replace a blown fuse with a fuse of the same type and rating:
1.
Remove the fuse holder at the back with an appropriate screwdriver (see picture).
2.
Remove the old fuse and install a new one.
3.
Place the fuse holder back.
Mounting the Device
•
Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms.
•
The carrying construction must be able to support 10 times the weight of the device for 1 hour without
deforming.
•
The installation must always be secured with a secondary attachment e.g. a safety cable.
•
Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified
technician check the device once a year and once before you bring it into service.
•
Install the device in a location with few passers-by that is inaccessible to unauthorised persons.
•
Overhead mounting requires extensive experience: calculating workload limits, determining the installation
material to be used… Have the material and the device itself checked regularly. Do not attempt to install
the device yourself if you lack these qualifications as improper installation may result in injuries.
•
Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws.
•
Make sure there is no flammable material within a 0.5 m radius of the device.
•
Have a qualified electrician carry out the electric connection.
•
Connect the device to the mains with the power plug. All devices must be powered directly off a grounded
switched circuit and cannot be run off a rheostat or dimmer circuit, even if the rheostat or dimmer channel
is used solely for 0 % to 100 % switching.
•
The installation has to be approved by an expert before the device is taken into service.
5.
Use
Switch the device on and off by means of the power switch (1). Do not operate the device
continuously. Adjust the output using the adjustment button (3).
5.1
Stand-Alone Mode
Control the rotating wheels using the switch (2) on the backside of the device. Put the
switch to I to rotate the wheels.
5.2
DMX Mode
DMX Channels
CHANNEL 1: wheel rotation => bubble output
DMX-512 Connection
When applicable, connect an XLR cable to the female XLR output of a controller (not incl.) and the other side to
the male XLR input of the device. Multiple devices can be linked through serial linking. The linking cable should
be a dual core, screened cable with XLR input and output connectors.