Table of burner and nozzle specifications – Indesit I5GG1G(W)-U Instrukcja Obsługi
Strona 11
11
GB
TECHNICAL DATA
Oven dimensions
(HxWxD)
34x39x 44 cm
Volume
58 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 18 cm
Power supply voltage
and frequency
see data plate
Burners
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
90/396/EEC dated 29/06/90 (Gas)
and subsequent amendments -
93/68/EEC dated 22/07/93 and
subsequent amendments -
2002/96/EC.
Table 1 (for Poland)
G20 (GZ50)
G2.350 (GZ35)
G30 (GPB)
Burner Diameter
(mm)
Thermal
Power
(p.c.i.*)
kW
Nozzle
1/100
(mm)
Flow*
l/h
Nozzle
1/100
(mm)
Flow*
l/godz
Thermal
Power
(p.c.i.*)
kW
Nozzle
1/100
(w mm)
Flow*
g/godz
Fast (Large)(R)
100 3,00 128
286
158
397 3,40 87 247
Semi Fast
(Medium)(S)
75 1,90 104
181
143
251 2,20 70 160
Auxiliary (Small)(A)
51
1,00
76 95 106
132 1,30 52 95
Oven
-
2,80 119
267
171 370 3,20 80 233
Supply Pressures
MINIMUM (mbar)
NOMINAL (mbar)
MAXIMUM (mbar)
16
20
25
10
13
16
29
37
44
* At 15°C 1013 mbar – dry gas
G20 (GZ50) p.c.i. = 37,78 MJ/m³
G2.350 (GZ35) p.c.i. = 27,20 MJ/m³
G30 (GPB) p.c.i. = 125,81 MJ/m³
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.
Table of burner and nozzle specifications
S S
R
A
(X)
Data plate, is located inside the flap or, after the oven
compartment has been opened, on the left-hand wall
inside the oven.
Safety Chain
! In order
to prevent
accidental
tipping of the
appliance, for
example by
a child clim-
bing onto the
oven door, the
supplied safety
chain MUST be
installed!
The cooker is fitted with a safety chain to be fixed by
means of a screw (not supplied with the cooker) to
the wall behind the appliance, at the same height as
the chain is attached to the appliance.
Choose the screw and the screw anchor according
to the type of material of the wall behind the applian-
ce. If the head of the screw has a diameter smaller
than 9mm, a washer should be used. Concrete wall
requires the screw of at least 8mm of diameter, and
60mm of length.
Ensure that the chain is fixed to the rear wall of the
cooker and to the wall, as shown in figure, so that
after installation it is tensioned and parallel to the
ground level.
I5GG1G U
ENERGY LABEL
and ECODESIGN
Regulation (EU) No 65/2014 supplemen-
ting Directive 2010/30/EU.
Regulation (EU) No 66/2014 implementing
Directive 2009/125/EC.
Standard EN 15181.
Standard EN 30-2-1