Part name – MPM 07-KPO-01 Instrukcja Obsługi

Strona 12

Advertising
background image

12

GB

THE MANUFACTURER WILL NOT ASSUME ANY RESPONSIBILITY IN CASE OF NON

ADHERENCE TO THESE INSTRUCTIONS.

KEEP THIS USER MANUAL CAREFULLY.

INSTALLATION

Selection of installation location

Keep the unit on a flat surface and dry place.

Leave at least 50cm space all around the unit.

Installation

Fix the exhaust pipe into the adapter, and then fix the other side of the exhaust pipe into the air outlet
vent of the unit. (anti-clockwise)
Fix the adapter into the window slider kit, then half open the window to meet the width of the window
slider kit. The length of the window slider kit is adjustable.

Incorrect mounting

The bend of the exhaust pipe is very important.

Incorrect mounting can prevent the machine from

working correctly.

Take care to prevent any sharp bows or bends of the

exhaust pipe.

The exhaust air must flow freely。

WARNING

The length of the exhaust pipe is specially designed according to the specification of this

product. Do not replace or prolong it with your own private hose as this could cause

mal-function.

BE CAREFUL: Use the shortest possible length which is 1500mm. When mounting, we

advise to keep the exhaust pipe in a horizontal position.

PART NAME

Front

1. Air outlet vent

2. Louver

3. Control panel

4. Knob

5. Castor

6. Handle

instrukcja_MPM-09-KPO-02.indd...12

2011-01-10...11:16:27

Advertising
Podręcznik ten jest związany z następujących produktów: