English – Philips HP6364 Instrukcja Obsługi
Strona 2
ENGLISH
General description (Fig. 1)
A
Comb
B
Hair length selector
C
Precision cutting element
D
Trimmer attachment
E
Release buttons
F
On/off slide
G
Socket for appliance plug
H
Protection cap (HP6364/HP6362 only)
I
Pretrimmer
J
Shaving foil
K
Shaver attachment (HP6364/HP6362 only)
L
Cleaning brush
M
Epilator attachment (HP6364 only)
N
Adapter
O
Charging light
P
Appliance plug
Important
Read this user manual carefully before you use the
appliance and save it for future reference.
Check if the mains voltage indicated on the adapter
corresponds to the local mains voltage before you
connect the appliance.
Only use the adapter supplied.
The adapter contains a transformer. Do not cut
off the adapter to replace it with another plug, as
this causes a hazardous situation.
Do not use the appliance if the adapter or the
appliance itself is damaged.
If the adapter is damaged, always have it replaced
with one of the original type in order to avoid a
hazard.
Make sure the adapter does not get wet.
Charge, store and use the appliance at a temperature
between 15°C and 35°C.
Even though this appliance is washable, it is intended
for dry use only. Do not use it in the shower or bath.
The appliance complies with the internationally
approved IEC safety regulations and can be safely
cleaned under the tap (Fig. 2).
Do not immerse the appliance in water.
Remove the appliance plug from the appliance
before you clean the appliance under the tap.
Be careful with hot water. Always check if the water
is not too hot, to prevent your hands from getting
burnt.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they
do not play with the appliance.
This appliance is only intended for trimming human
hair. Do not use it for any other purpose.
To prevent damage and injuries, keep the running
appliance away from scalp hair, eyebrows, eyelashes,
clothes, threads, cords, brushes etc.
Noise level: Lc = 72 dB(A)
Electromagnetic fields (EMF)
This Philips appliance complies with all standards
regarding electromagnetic fields (EMF). If handled
properly and according to the instructions in this user
manual, the appliance is safe to use based on scientific
evidence available today.
Charging
It takes 12 hours to charge the appliance fully.
When the appliance is fully charged, it has a cordless
operating time of up to 35 minutes.
Do not leave the appliance connected to the mains for
more than 24 hours.
1
Make sure the appliance is switched off when you
start to charge it.
2
Insert the appliance plug into the appliance (Fig. 3).
3
Insert the adapter into the wall socket.
The charging light goes on (Fig. 4).
4
If the battery is empty and you want to trim your
bikini line, charge the appliance for at least 2 hours.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
,
The battery then has enough power for 10 minutes
of trimming.
Optimising the lifetime of the battery
When you first start to use the appliance, we advise
you to use it until the battery is completely empty
before you recharge it. Repeat this procedure 2 or
3 times.
Discharge the battery completely twice a year by
letting the motor run until it stops.
Using the appliance
Even though this appliance is washable, it is intended for
dry use only. Do not use it in the shower or bath.
Remove the appliance plug from the appliance before
you start to use it.
Do not press the appliance too firmly onto the skin and
stretch the skin with your free hand during use.
Note: Do not move the appliance too fast. Make smooth and
gentle movements.
Attaching and detaching attachments.
1
To attach the attachment, put it on the appliance
and push it home (‘click’). (Fig. 5)
2
To detach the attachment, press the release buttons
and remove the attachment (Fig. 6).
Trimming with the comb
Use the comb to trim your bikini line.
1
Put the trimmer attachment on the appliance and
put the comb on the trimmer attachment (‘click’).
2
Slide the comb to the desired hair length
setting (Fig. 7).
Hair length settings
The adjustable comb with 4 settings allows you to cut
hair to 4 different lengths:
Setting
Hair length after cutting
1
2.5mm
2
4.5mm
3
7mm
4
9.5mm
Start at the setting for maximum hair length (setting 4) to
familiarise yourself with the trimmer attachment.
The selected setting is shown on the display on the
back of the comb (Fig. 8).
1
Push the on/off slide upwards to switch on the
appliance.
2
Move the trimmer attachment against the direction
of hair growth. Make sure the surface of the comb
always stays in contact with the skin (Fig. 9).
3
When you have finished trimming, press the release
buttons on the comb and remove the comb.
Styling with the precision cutting element
To style your bikini line, hold the appliance with the teeth
of the cutting element pointing towards your skin.
1
Remove the comb and/or any attachment and put
the trimmer attachment (without comb) on the
appliance.
Styling without the comb results in a hair length of
approx. 1mm.
2
Push the on/off slide upwards to switch on the
appliance.
3
Move the appliance towards the desired contour
of your bikini line. Touch the hair lightly with the
precision cutting element.
You can be as creative as you like when you style your
bikini line. You can even draw and cut out a template, for
instance a heart shape, which you can use to create a
personal style.
Shaving with the shaver attachment
(HP6364/HP6362 only)
1
Remove the comb and/or any attachment and put
the shaver attachment on the appliance.
-
-
,
,
2
Push the on/off slide upwards to switch on the
appliance.
3
Move the appliance with the teeth of the
pretrimmer pointing forwards against the direction
of hair growth to precut longer hairs (Fig. 10).
4
Then turn the appliance so that the shaving foil
points forwards to achieve a smooth shaving
result (Fig. 11).
Epilating (HP6364 only)
Keep the epilator attachment away from water.
Consult your doctor before you use the epilator
attachment on irritated skin or skin with varicose veins,
rashes, spots, moles (with hairs) or wounds. People with
a reduced immune response or people who suffer from
diabetes mellitus, haemophilia or immunodeficiency
should also consult their doctor first.
Your skin may become a little red and irritated the
first few times you use the epilator attachment.
This phenomenon soon disappears as your skin
gets used to epilation and the hairs that grow back
become thinner and softer. If the irritation does not
disappear within 3 days, we advise you to consult
your doctor.
1
Remove the comb and/or any attachment and put
the epilator attachment on the appliance.
2
Place the appliance perpendicularly onto the skin
so that the epilator attachment is in proper contact
with the skin.
3
Stretch the skin with your free hand to make the
hairs stand upright.
4
To epilate your bikini line, move the appliance
slowly against the direction of hair growth (Fig. 12).
Do not exert any pressure.
Cleaning and maintenance
Never use scouring pads, abrasive cleaning agents or
aggressive liquids such as petrol or acetone to clean the
appliance.
You can also clean the appliance and the attachments,
except for the epilator attachment, under the tap.
1
Switch off the appliance, pull the adapter out of the
wall socket and pull the appliance plug out of the
appliance.
2
Remove any attachments and clean the appliance
and the attachments.
Cleaning the precision cutting element
and the comb
1
Pull the precision cutting element in the direction
of the arrow to remove it (Fig. 13).
2
Clean the precision cutting element, the cavity
under the precision cutting element and the comb
with the brush supplied or under the tap.
3
Insert the hook of the cutting element into the
slot in the cavity and push the cutting element back
onto the appliance (‘click’) (Fig. 14).
Cleaning the shaver attachment
1
Pull the foil frame in the direction of the arrow to
remove it (Fig. 15).
2
Clean the cutter and its surroundings and the cavity
in the foil frame carefully with the brush or under
the tap (Fig. 16).
Cleaning the epilator attachment
Never try to remove the epilating discs from the
epilator attachment.
Do not clean the epilator attachment under the tap.
Epilation can lead to ingrown hairs or minor skin
injuries, which may cause inflammations due to
penetration of bacteria into the skin. It is therefore
important to clean the epilator attachment
thoroughly after each use.
1
Switch off the appliance, remove the epilator
attachment and clean all accessible parts and the
epilating discs with the cleaning brush. (Fig. 17)
,
,
4239.002.6409.2
2/11